Passive fire protection isn’t finished when the work is complete.

Buildings change.

Contractors move on.

People change roles.

The record should still explain what was done, where it was done, and how it was done.

01What we do

Compartmentation, across the life of a building.

A compartment divided into four: compartmentation, fire stopping
                        and fire doors, with the promise in the brass cell.

Passive fire protection is what holds a fire in the space it started in: the compartment walls and floors, the doors in them, and the seals around everything that passes through. Fire doors, fire stopping and compartment construction are all parts of that same line. We install it, check it and inspect it afterwards.

02One package or all of it

We can take the package, or the whole of the works.

The compartment line rarely sits in empty space. Putting it right means opening the ceiling, taking the wall down, moving the services and putting it all back, which is usually somebody else’s contract.

We take the compartmentation package under a main contractor, or we contract for all of it and hand back a finished room. Not many compartmentation businesses can do both.

03Why it is different

A buildingthat can answerfor itself.

When we finish, the building holds a coherent record of its own compartmentation: what is installed, where, to what specification, by whom, checked by whom, and how it should be maintained.

It is what the work leaves behind, captured while the ceiling is still open, because that is the only moment most of it can be captured at all.

04What that looks like

Three rows of a real register.

This is what you are handed at the end of a job. One row per element, structured to go straight into the building’s golden thread without anybody having to retype it.

The outcome is a controlled value, not an opinion. An empty cell means not yet recorded, and never means compliant.

COMP-REG-001 Fire Door Register Extract. Every fire door assembly in the building, its specification, its condition and the evidence held for it.
Asset refLevel Core / areaRoom / location Classification Certification evidence OutcomeDefects open
FD-00103East core Flat 301 entranceFD30S Leaf label, frame unverified Assess1
FD-00203East core Riser cupboardFD60S Leaf and frame labelled Pass0
FD-00304West core Lobby to stairFD30S Documentary, leaf damaged Replace3

Built to withstand scrutiny.

Installed. Inspected. Evidenced.

Make an enquiry

Or speak to one of us directly.